Product center

Classification

MORE
Go back>>PRODUCTS

Marine cable sheathing compound (XH-21A)

  According to GB/T759 4.9-87 standard production; that is, 85~C generally does not extend the rubber sheathing compound. It is used for general cable sheathing of conductors with long-term working temperature of 85~C. It has certain oil/heat/cold/weather resistance and high flame retardancy. It can be used directly as a marine cable sheath and can completely replace chlorine. Butadiene rubber (CR) compound.


Before agingTensile strength ≥Mpa11.012.7
Elongation at break ≥%300440
Air box aging testAging conditiontemperature℃75±275±2
time 7×247×24
Tensile strength after aging≥Mpa//
Rate of change ≤%-30-3
Elongation at break after aging≥%200402
Rate of change ≤%-40-13
Thermal extension testTest conditionsAir temperature℃200±3200±3
Load timemin1515
Mechanical stressN/mm²0.20.2
Elongation under load ≤%17520
Permanent deformation after cooling ≤%154
Oil immersion testTest conditionsOil temperature℃100±2100±2
Oil immersion testH2424
Tensile strength change rate ≤%-40-5
Elongation at break elongation rate ≤%-40-3
Marine cable sheathing compound (XH-21A) 2019-8-30 本文被阅读 4978 次
PREV:Mining cable sheathing compoundNEXT:XH-01A{or SE4} sheathing compound